PRODUCT NAME SLH99 Epoxy phosphoric acid zinc primers

BRIEF Two Pack anti-corrosive Primer made from Epoxy resin, zinc phosphate and curing agent

FEATURES 
-Excellent adhesion on prepared substrate, good adhesion to next coat
-Good resistance to abrasion and impact
-Can be exposed to atmosphere and immersed in water
-Excellent chemical resistance

RESISTANCE GUIDE

HEAT RESISTANCE   Up to 140℃ dry heat
WEATHERABILITY      Some chalking will occur with exterior exposure.
SOLVENTS          Resistance to steep of solvent oil, gasoline, diesel oil, lubricating oil
ACIDS                   Suitable for splash and spillage to organic and inorganic acid
ALKALIS               Suitable for splash and spillage to the most common alkalis
SALTS                  Resists immersion of neutral and alkali salts.
WATER                Excellent resistance to immersion in fresh and salt water
ABRASION         Good when fully cured.

USES:Widely used in the shipping, oil platforms, Bridges, Marine facilities, mining machinery, piping, steel structure, chemical processing plants protection ,etc.

TYPICAL PROPERTIES AND APPLICATION DATA
COLOR                         Grey
DENSITY                      1.35kg/L  
SOLIDS BY VOLUME             41%   
SOLIDS BY WEIGHT              76%
SPREADING RATE               7.6 m2/kg  (40um DFT)
DRYING TIME(23℃)             Touch  4 Hr    Handle  24 Hr    Full cure 7Days
OVERCOAT INTERVAL(23℃)       Min 8 Hr   Max 7 Days 
STORAGE                               at least 12 months (dry, cool and under cover )
PACKAGING                           Part A: 21kg   Part B: 3kg
MIXING RATIO (m/m)            Part A : Part B=7:1
CURE TIME(23℃)                10min
POT LIFE(23℃)                     4 Hr

DIRECTIONS  Before using stir or using dynamic mixer mixing two components completely,Just mix a good raw material and mixing of raw materials before can not be together. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir.
Overmuch thinner will lead sag and slow cure rate, thin film, thinner should be added after mixed. Practical spreading rates may be reduced 5%—80% for wastage of different application conditions.

APPLICATION  

STEEL: Steel surface must be prepared by abrasive blast cleaning to ISO Standard Class Sa2.5 or power tool cleaning Class St3. Primer surface must keep dry and clean. The primer surface of damage, wedding and rusting must be prepared to Sa2.5 or St3. Zinc salt on the primer must be removed by abrasive or fresh water blasting.
 Don’t apply at air temperature below 5℃ or above 40℃. Don’t apply at relative humidity above 85% or when air temperature is less than 3℃ above the dew point.
 Don’t apply if there is fog, rain, snow or strong wind. 
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-15% with Epoxy Thinner X-2. Additional coats may be required to attain specified thickness. 
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-15% of Epoxy Thinner X-2 can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-5% of Epoxy Thinner X-2 can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.38-0.48 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
CLEAN UP: with Epoxy Thinner X-2

SAFETY:Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists.
Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.

Notes: The data in the manual is get from standard experiments and may be vary from different conditions in use. Please refer to the latest manual if the data is altered and we would not inform specially.

 