Introduction to products
PRODUCT NAME SLBS05 Cold-cold insulation glue
BRIEF By acrylic resins, pigments and fillers, insulation material, additive etc paint.
FEATURES
-Excellent ageing .
-Excellent chalking and cracking resistance
-Yellowing will not occur with long-term exposure
-Excellent color and gloss retention
RESISTANCE GUIDE
HEAT RESISTANCE Up to 120℃ dry heat
WEATHERABILITY Excellent color and gloss retention with exterior exposure
SOLVENTS Resists Aliphatic solvent and resistance mineral spatter and overflow.
ACIDS Suitable for splash and spillage of most acids
ALKALIS Suitable for splash and spillage of most alkalis
SALTS Unaffected by splash and spillage to neutral and alkali salts
WATER Excellent resistance to splash and spillage of fresh and salt water
ABRASION Good when fully cured.
USES:Widely used in metal tins, trough equipment, oil tank, youchegang outer, gas spherical tanks, chemical raw materials cans, chemical pipeline equipment and refrigerator etc on heat insulation cooling effect..
TYPICAL PROPERTIES AND APPLICATION DATA
COLOR white
DENSITY 1.2 g/cm3
SOLIDS BY VOLUME 30%
SPREADING RATE 8.3 m2/kg (30um DFT)
DRYING TIME(23℃) Touch ≤4 Hr Handle ≤24 Hr
OVERCOAT INTERVAL(23℃) Min 24Hr
STORAGE(dry, cool ) At least 12 months
FLASH POINT 23℃
PACKAGING 20kg per barrel
DIRECTIONS Stir contents of each can thoroughly with a broad flat stirrer using a stirring, lifting action or use a power mixer. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir.
Overmuch thinner will lead sag and slow cure rate, thin film. Practical spreading rates may be reduced 5—80% for wastage of different application conditions.
APPLICATION STEEL: Round off all rough welds, sharp edges and remove weld spatter. Remove grease, oil and other contaminants. Steel surface must be prepared by abrasive blast cleaning to ISO Standard Class Sa2.5 or power tool cleaning Class St3.
Don’t apply at air temperature below 5℃ or above 45℃. Don’t apply at relative humidity above 85% or when air temperature is less than 3℃ above the dew point.
Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-15% with Special Thinner X-98. Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-15% of Special Thinner X-98can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-15% of Special Thinner X-5 can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.33-0.38 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
CLEAN UP: with Special Thinner X-5
SAFETY:Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists. Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.
Notes: The data in the manual is get from standard experiments and may be vary from different conditions in use. Please refer to the latest manual if the data is altered and we would not inform specially.